For industrial wastewater, domestic sewage, and environmental compliance monitoring, the ERUN-SP3-J4A portable infrared spectrophotometric oil analyzer achieves a minimum detection concentration of 0.004 mg/L with repeatability of RSD ≤ 0.6%, fully compliant with China's HJ637-2018 standard and backed by CE, ISO 9001, and RoHS certifications.

ERUN-SP3-J4A the Right Oil in Water Analyzer

1. What Makes ERUN-SP3-J4A the Right Oil in Water Analyzer?

The ERUN-SP3-J4A is a portable infrared spectrophotometer specifically developed for the determination of petroleum hydrocarbons and animal/vegetable oils in water. It delivers lab-grade accuracy in a field-deployable 8 kg package, with a measurement range of 0–5000 mg/L and full-spectrum scanning completed in 60 seconds per scan.

Technical Specifications at a Glance

Parameter

Specification

Measurement Items

Petroleum hydrocarbons, animal/vegetable oils in water

Absorbance Range

0.0000–2.0000 AU (100–1% T)

Minimum Detection Concentration

0.004 mg/L

Repeatability

RSD ≤ 0.6% (11 determinations of 30–40 mg/L oil standard)

Instrument Detection Limit

DL ≤ 0.03 mg/L

Method Detection Limit

0.06 mg/L (500 mL sample, 50 mL extract)

Measurement Range

0–5000 mg/L

Accuracy

≤ ±5%

Wavenumber Range

3400–2400 cm⁻¹ (2941–4167 nm)

Scan Speed

60 seconds per full spectrum scan

Weight

8 kg

Operating Temperature

-5 to 45°C

2. Which Industries Need Portable Oil in Water Testing?

Environmental monitoring agencies, industrial wastewater treatment plants, power generation facilities, petrochemical plants, steel mills, and municipal water authorities all require reliable oil-in-water analysis for regulatory compliance and process control.

The ERUN-SP3-J4A is deployed across multiple sectors:

  • Environmental Protection: Surface water, groundwater, domestic sewage, and industrial wastewater monitoring

  • Petroleum & Petrochemical: Cooling water and wastewater oil content monitoring in refining and processing

  • Power Generation: Thermal power plants and steel mills monitoring circulating water and effluent

  • Agriculture: Irrigation and production water quality testing

  • Municipal Water: Water supply and drainage authorities conducting routine oil content analysis

3. How Does Infrared Spectrophotometry Measure Oil in Water?

Infrared spectrophotometry measures oil concentration by detecting the characteristic absorption of C-H bonds in petroleum hydrocarbons at specific wavenumbers (3400–2400 cm⁻¹), with the absorbance value directly proportional to oil concentration according to the Lambert-Beer law.

The ERUN-SP3-J4A follows the HJ637-2018 standard, which specifies the infrared spectrophotometric method for determining petroleum and animal/vegetable oils in industrial wastewater and domestic sewage. When sampling 500 mL with a 50 mL extract volume using a 4 cm quartz cuvette, the method detection limit reaches 0.06 mg/L with a quantitation limit of 0.24 mg/L.

4. What Certifications Does This Oil Analyzer Hold?

The ERUN-SP3-J4A is fully certified with CE (EU safety, health, and environmental compliance), ISO 9001 (quality management system), and RoHS (restriction of hazardous substances), ensuring regulatory acceptance across global markets.

These certifications mean:

  • CE Marking: Complies with EU mandatory requirements for product safety and environmental protection

  • ISO 9001: Manufactured under strict quality management system standards with refined production control

  • RoHS Compliance: Free from restricted hazardous substances, meeting international environmental standards

For buyers in Europe, North America, and other regulated markets, these certifications eliminate compliance barriers and streamline import clearance.

5. Why Choose ERUN-SP3-J4A Over Other Portable Oil Analyzers?

The ERUN-SP3-J4A combines field-portable convenience (8 kg, -5 to 45°C operation) with laboratory-grade precision (0.004 mg/L detection, RSD ≤ 0.6%) at a competitive price point, backed by full international certifications.

Key differentiators include:

  1. Simplified Operation – Built-in 7-inch color touchscreen with visualized interface and guided operating procedures eliminates the need for extensive operator training.

  2. Intelligent Calibration – Automatic start-up calibration, standard curve calibration, and correction factor calibration ensure accuracy without manual intervention.

  3. Comprehensive Data Management – Records sample IDs, test times, results, and extractant types; connects to Windows PCs for spectral scanning and data processing.

  4. Built-in Printing – Integrated printer outputs stored data and full spectral scans directly in the field.

  5. Durable Light Source – Precision grating system with operational lifespan exceeding 6,000 hours reduces maintenance costs and downtime.

  6. Complete Accessory Kit – Includes extraction funnel, glassware, petroleum hydrocarbon standard solution, and all auxiliary accessories needed for immediate deployment.

6. How to Select the Right Oil in Water Analyzer for Your Application?

When selecting an oil in water analyzer, prioritize instruments with wide measurement ranges (0–5000 mg/L), low detection limits (below 0.1 mg/L), international certifications (CE, ISO 9001), and field-proven durability in harsh environments.

Selection Factor

ERUN-SP3-J4A Performance

Detection Sensitivity

0.004 mg/L minimum detection

Measurement Range

0–5000 mg/L, covers most applications

Portability

8 kg, operates -5 to 45°C

Certifications

CE, ISO 9001, RoHS

Ease of Use

7-inch touchscreen, guided operation

Data Output

Built-in printer, PC connectivity

7. Frequently Asked Questions

Q: What is the minimum detection limit of the ERUN-SP3-J4A?

A: The instrument achieves a minimum detection concentration of 0.004 mg/L, with an instrument detection limit of DL ≤ 0.03 mg/L.

Q: Which standard does this analyzer comply with?

A: The ERUN-SP3-J4A is developed in accordance with China's HJ637-2018 "Water Quality – Determination of Petroleum and Animal and Vegetable Oils – Infrared Spectrophotometry."

Q: Is this analyzer suitable for field use?

A: Yes. At 8 kg with a -5 to 45°C operating range and 7-inch touchscreen interface, it is designed for portable field deployment.

Q: What certifications does the product hold?

A: CE, ISO 9001, and RoHS certifications ensure regulatory compliance for global markets.

Q: What is the measurement range?

A: 0–5000 mg/L, with accuracy of ≤ ±5%.

Q: How long does a single measurement take?

A: Full spectrum scan completes in 60 seconds.

Get the Complete Technical Specifications

The ERUN-SP3-J4A portable infrared spectrophotometric oil analyzer is your solution for accurate, compliant, and portable oil-in-water testing across environmental, industrial, and municipal applications. With CE, ISO 9001, and RoHS certifications, it meets the regulatory requirements of global markets while delivering the precision you need for confident decision-making.

View the full product specifications and request a quote: