Types of water | Analysis items | Daily water supply capacity (10000 cubic meters) | ||
≥50 | <50 - ≥10 | <10 | ||
Testing frequency | Testing frequency | Testing frequency | ||
Raw water | turbidity, chromaticity, visible substances, CODMn | Once a day | Once a day | Once a day |
aerobic bacterial count, total coliforms, thermotolerant coliforms | Once a week | Once a week | Once every two weeks | |
Tap water | turbidity, chromaticity, visible substances, CODMn, aerobic bacterial count, total coliforms, thermotolerant coliforms, residual chlorine | Once a day | Once a day | Once a day |
Terminal tap water | turbidity, chromaticity, visible substances, CODMn, aerobic bacterial count, total coliforms, thermotolerant coliforms, residual chlorine | Twice a month | Twice a month | Twice a month |
1、If total coliform bacteria are detected in the factory water and the water at the end of the pipeline network, further testing of fecal coliform bacteria is required. 2、The inspection items and frequency of harmful substances outside this table shall be determined by the local health administrative department and water supply unit according to specific circumstances. |
Serial No. | Items | Limiting value | Standard basis |
1 | turbidity | 1 NTU | GB 5749-2022 Standards for drinking water quality |
2 | chromaticity | 15 PCU | |
3 | CODMn | 3 mg/L | |
4 | aerobic bacterial count | 100 MPN/mL or CFU/mL | |
5 | total coliforms | Should not be detected | |
6 | thermotolerant coliforms | Should not be detected | |
7 | residual chlorine | Contact time with water≥30 min Tap water and terminal tap water≤2 mg/L Margin of tap water≥0.3 mg/L Margin of terminal tap water ≥0.05 mg/L |
Serial No. | Items | Measuring range | Unit | Maximum deviation | Analysis methods | Standard basis |
1 | turbidity | 0-400 | NTU | ≤2%(F.S.) | Scattering method - Formazine standard | GB/T 5750.4 |
2 | chromaticity | 5-500 | PCU | 3%(F.S.) | Platinum cobalt standard colorimetric method | GB/T 5750.4 |
3 | CODMn | 0.00-10.00 | mg/L | 0.2 or 5% | Acidic potassium permanganate spectrophotometric method | GB/T 5750.7 |
4 | aerobic bacterial count | —— | pcs/L | —— | Plate count method | GB/T 5750.12 |
5 | total coliforms | —— | pcs/L | —— | Multi tube fermentation method | GB/T 5750.12 |
6 | thermotolerant coliforms | —— | pcs/L | —— | Multi tube fermentation method | GB/T 5750.12 |
7 | residual chlorine | 0.02-10.00 | mg/L | 5%(F.S.) | Titrimetric method using N,N-diethyl-1,4-phenylenediamine | GB/T 5750.11 |
Serial No. | Part Number | Name | Items | Pictures |
1 | ERUN-SP-M9000 | Portable multi-parameter water quality tester | turbidity, chromaticity, CODMn, residual chlorine | |
2 | ERUN-SP-MD690 | Portable water quality microbiological tester | aerobic bacterial count, total coliforms, thermotolerant coliforms |
Note:Analysis parameter items can be flexibly combined and selected according to the customer's own needs.
Serial No. | Name | Specifications | Quantity |
1 | Colorimetric tube | Ф25×95mm | 10 |
2 | Test tube rack | White | 2 |
3 | Pipette gun | Minimum graduation 0.1mL | 1 |
4 | Cuvette | 70×25×70mm | 2 |
5 | Lens hood | black | 1 |
6 | CODMn reagent | 100 times/set | 1 |
7 | residual chlorine reagent | 100 times/set | 1 |
8 | water bath | Constant temperature, resolution 0.1 ℃ | 1 |
9 | biochemical incubator | ERUN-SHX100 | 1 |
10 | temperature electrode | / | 1 |
11 | pH composite electrode | / | 1 |
12 | chargers and charging cables | / | 1 |
13 | USB cable | / | 1 |
14 | product manual | / | 1 |
15 | product certificate /product warranty card | / | 1 |
Note:Analysis parameter items can be flexibly combined and selected according to the customer's own needs.