Home
>
Products
>
On-line water quality monitoring equipment
>
Water quality sodium Na online analyzer

ERUN-SZ3-M6

Water quality sodium Na online analyzer
Widely used in water supply, drainage monitoring, aquaculture monitoring, environmental monitoring and industrial production and other areas of water quality sodium ion concentration real-time monitoring.
Water quality sodium Na online analyzer
Water quality sodium Na online analyzer
Introduction

Brand: Erun

Water quality sodium Na online analyzer

Model: ERUN-SZ3-M6

Parameter: Sodium

ERUN-SZ3-M6 online water sodium ion analyzer developed and produced by Erun Environmental Protection adopts brand-new design concept and advanced technology, continuously monitors sodium ion concentration, PH value, conductivity, temperature and other parameters in water, with more reliable measurement results, which can be applied in power plant, petrochemical, paper making, metallurgy, residual heat, etc. It is suitable for continuous measurement of sodium ion content of sun bed water, boiler, steam, condensate in the industries of thermal power generation, chemical industry, metallurgy, papermaking and so on. It is suitable for continuous measurement of sodium ion content in sun bed water, boiler and condensate in thermal power generation, chemical industry, metallurgy, paper making and other industries.

Parameters

Water quality sodium Na online analyzer  ERUN-SZ3-M6:

Measurement range

0-200 µg/L,0-10 mg/L

oscillometric error

±0.05pNa或±0.5μg/L

resolution 

0.01pNa,0.01µg/L

thermocompensating electrode

PT1000

water temperature

5-45℃

Warming range

5-45℃,25℃为基准温度

water pressure

小于0.6MPa

water flow

100-200mL/min

electric power source

220 V/30W


Features

Water quality sodium Na online analyzer  ERUN-SZ3-M6:

1. The display is a 7-inch color touch screen, with a beautiful display interface, friendly man-machine interface and easy operation;

2. Measuring sodium ion, PH and conductivity values of water samples at the same time, it can reliably monitor the sodium ion content in water samples;

3. Measurement is automatically resumed when water comes in;

4. Calibration using two standard solutions, calibration process iteratively calculated; standard solution in the background sodium content, to eliminate the impact of background sodium;

5. Increase the emptying valve, the water sample is completely emptied after each measurement, change the measurement mode of mixing new and old water samples in the measurement cell, more accurate measurement, better real-time;

6.With large capacity data storage function, data query is convenient;


+8602985515255
yrhb@erunwas.com