ERUN-SZ4-A-J4C

On-line analyzer for oil (PAHs) water quality in water
Widely used for real-time continuous monitoring of oils (PAHs).
On-line analyzer for oil (PAHs) water quality in water
On-line analyzer for oil (PAHs) water quality in water
On-line analyzer for oil (PAHs) water quality in water
On-line analyzer for oil (PAHs) water quality in water
On-line analyzer for oil (PAHs) water quality in water
On-line analyzer for oil (PAHs) water quality in water
Introduction

Brand:Erun 

On-line analyzer for oil (PAHs) water quality in water

Model:ERUN-SZ4-A-J4C

Parameter:Oil (UV fluorescence method)

The ERUN-SZ4-A-J4C online water quality analyzer for oil (PAHs) in water, developed and manufactured by Erun Environmental Protection, stands out for its excellent efficiency and swiftness, and shows excellent measurement repeatability. The instrument is designed for real-time monitoring of ppb-level trace oil content in water bodies, ensuring accurate data. A dedicated sensor with integrated self-cleaning brush function eliminates air bubbles and oil residues and significantly reduces the risk of contamination interfering with the results, thus significantly extending maintenance intervals. Even under long-term online operation, ERUN-SZ4-A-J4C can maintain excellent stability performance, providing reliable monitoring and early warning service for oil pollution in water, which is a powerful assistant in the field of environmental protection monitoring.

Parameters

Technical parameters of the sensor of ERUN-SZ4-A-J4C on-line analyzer for oil (PAHs) water quality in water:

Measurement range

0-1100ppb(BTEX)、0-1000 ppb(PAH)、0-60ppm(BTEX)

temperature range

0~50℃

resolution 

0.01

linearity

R2>0.999(Continuous dilution of standard solution)

sensor interface

RS-485,MODBUS protocol

protection class

IP68

calibrations

Zero, one or two point calibration

Cable Length

Standard 10m, customizable

Maximum pressure

3bar

Self-cleaning system

power supply

DC12~24V,Current > 1A

sizes

Φ50mm*176.3mm

Housing Material

316L (custom titanium alloy available)

Technical parameters of ERUN-SZ4-A-J4C on-line analyzer controller for oil (PAH) in water:

demonstrate

LED liquid crystal display

Automatic temperature compensation

0~60℃

signal output

0~20mA(Load resistance<750Ω)

4~20mA(Load resistance<750Ω)

Power supply

85~265VAC±10%,50±1Hz,Power ≤3W;

9~36VDC,Power ≤3W

communication output

RS485 Modbus RTU

environmental temperature

-10℃~60℃

relative humidity

Not more than 90%

sizes

144mm*144mm*130mm

Installation

Recessed (Opening size 138*138mm)

weights

0.5kg

Features

ERUN-SZ4-A-J4C Oil in water (PAHs) water quality online analyzer sensor functional characteristics:

On-line measurement of PAH (oil) content in water by UV fluorescence method with high sensitivity;

Imported high-precision 254nm UV LED light source, high stability, small drift, long life;

254nm excitation light, higher sensitivity for refined oil measurement;

With self-cleaning brush to prevent microbial adhesion and long maintenance intervals;

Adopts RS485 digital output and supports Modbus protocol;

Built-in calibration parameters for easy field use and secondary calibration.

ERUN-SZ4-A-J4C Oil in Water (PAHs) Water Quality On-line Analyzer Controller Functional Features:

Adopt LED LCD display, intelligent Chinese/English menu operation;

Output signal: software selects 0-20mA or 4-20mA output;

High-resistance preamplifier: high input impedance, anti-noise, strong anti-interference ability;

Multi-parameter display on the same screen: Simultaneously display pH (or ORP) value, temperature value, two current outputs and relay working status;

Self-set password: Users can set or change their own passwords to avoid misuse by uninvolved personnel.
+86 18166600151