Brand: Erun

Portable multi-parameter water quality analyzer

Model number:ERUN-SP6-8

Parameters: COD, copper,  other 35 parameters.

Erun environmental protection research and development production of  ERUN-SP6-8 portable multiparameter water quality analyzer is a measurement of various parameters of portable water quality analysis instrument, the instrument with cold light source, narrow band interference, optical system, stable optical performance, with PID automatic temperature control, timing, and other functions, convenient instrument, simple operation, suitable for the field, field use.


Parameters

1.Number of channels: 8 channels

2.Wavelength: 420nm, 440nm, 470nm, 510nm, 520nm, 540nm, 560nm, 600nm, 610nm, 630nm, 660nm, 700nm can customize any 8 wavelengths in the above range.

3.Wavelength precision: central wavelength ± 1nm .

4.Measurement parameters: 35 parameters, including CODMn, copper, iron, nickel, hexavalent chromium, phosphate, and nitrite, Customers can customize the measured parameters as needed.

5.Optical stability: the drift of the absorbance in 20min is less than 0.002A.

6.Measuring parameters

numberparameter

measurement range

uniterror
1Ammonia nitrogen (low range)0.02-5.00mg/L3%(F.S)
2Ammonia nitrogen (high range)5.00-25.00mg/L3%(F.S)
3CODMn (Permanganate index)0.00-10.00mg/L0.2 or 5%
4Residual chlorine (low range)0.02-2.00mg/L0.1 or 5%
5Residual chlorine (high range)2.00-10.00mg/L5%
6Total chlorine (low range)0.02-2.00mg/L0.1 or 5%
7Total chlorine (high range)2.00-10.00mg/L5%
8Chlorine dioxide (low range)0.05-2.00mg/L0.2 or 5%
9Chlorine dioxide (high range)2.00-20.00mg/L5%
10Sulfate5-200mg/L5%
11Nitrate (nitrogen)0.02-10.0mg/L0.1or 5%
12Phosphate(low range0.01-10.0mg/L0.2 or 5%
13Phosphate(high range10.0-50.0mg/L5%
14Nitrite nitrogen(low range0.02-1.0mg/L0.05 or 5%
15Nitrite nitrogen(high range1.0-5.0mg/L5%
16Sulfides0.005-1.000mg/L5%(F.S)
17Fluoride0.05-2.0mg/L5%(F.S)
18Cyanide0.01-0.50mg/L5%(F.S)
19Bromide0.10-5.00mg/L5%(F.S)
20Formaldehyde0.05-2.5mg/L5%(F.S)
21Volatile phenol  (low range)0.20-5.0mg/L5%(F.S)
22Volatile phenol  (high range)5.0-10.0mg/L5%(F.S)
23Hydrazine0.01-0.50mg/L5%(F.S)
24Aniline compoun (low range)0.03-1.0mg/L5%(F.S)
25 Aniline compoun(high range1.0-5.0mg/L5%(F.S)
26Silica0.01-5.00mg/L5%(F.S)
27Total alkalinity (low range)0-100mg/L5%(F.S)
28Total alkalinity (high range)100-1000mg/L5%(F.S)
29Total hardness (low range)0.1-5.0mg/L5%(F.S)
30Total hardness (high range)5.0-200.0mg/L5%(F.S)
31Chloride ion (chloride)0.20-100.0mg/L5%(F.S)
32 Copper (low range)0.02-1.0mg/L5%(F.S)
33 Copper (high range)1.0-10.0mg/L5%(F.S)
34Zinc0.2-5.0mg/L5%(F.S)
35Nickel (low range)0.02-0.50mg/L5%(F.S)
36Nickel (high range)0.10-10.0mg/L5%(F.S)
37Nickel 
0.02-10.0
mg/L
5%(F.S)
38Iron (low range)0.0-5.0mg/L5%(F.S)
39Iron (high range)5.0-10.0mg/L5%(F.S)
40Hexavalent chromium0.01-1.00mg/L5%(F.S)
41Cadmium 0.05-0.50mg/L5%(F.S)
42Manganese (low range)0.01-0.10mg/L5%(F.S)
43Manganese (high range)0.10-1.0mg/L5%(F.S)
44Manganese 0.02-5.00mg/L5%(F.S)
45Total chromium0.02-1.0mg/L5%(F.S)
46Aluminum (low range)0.01-0.40mg/L5%(F.S)
47Aluminum (high range)0.40-4.00mg/L5%(F.S)
48Silver0.01-1.00mg/L5%(F.S)
49Molybdenum0.05-1.00mg/L5%(F.S)
50Arsenic (low range)0.004-0.100mg/L5%(F.S)
51Arsenic (high range)0.100-0.500mg/L5%(F.S)
52Beryllium0.001-0.10mg/L5%(F.S)
53Boron0.10-2.00mg/L5%(F.S)
54Mercury0.002-0.50mg/L5%(F.S)
55Lead0.01-0.50mg/L5%(F.S)
56Chroaticity (low range)5-50PCU3%(F.S)
57Chroaticity (high range)50-500PCU3%(F.S)
58 Turbidity0-400NTU≤2%(F.S)
59Suspended solids5-1000mg/L≤2%(F.S)
60PH(Electrode method)0.00-14.00PH±0.01
61Dissolved oxygen (colorimetric method)0.1-10.0mg/L0.1±5%
62Ozone0.01-2.5mg/L5%(F.S)
63Anionic surfactants0.01-1.0mg/L5%(F.S)
64Available chlorine0.0-150.0mg/L5%(F.S)
65 Chlorite0.00-20.00mg/L5%(F.S)
66 Stibonium (Sb)0.05-10.0mg/L5%(F.S)
67
Iodide
0.02-1.00
mg/L
5%(F.S)
68barium
0.00-5.00
mg/L
5%(F.S)


Features

1.Cold light source, narrow-band interference optical system, with good optical stability.

2.When measuring the sample, the wavelength is automatically selected without adjustment.

3.The optical part of the instrument is strictly controlled to ensure its high performance.

4.There is a USB port that can be connected to a computer to record reads or print out the stored data.

5.LCD large-screen LCD display, convenient and intuitive operation.

6.Main engine case adopts molded ABS material, IP65 design, good waterproof and dustproof performance.

+86 18166600151
yrhb@erunwas.com