Hardness, phosphate, dissolved oxygen, turbidity, etc.
ERUN-SZ-C40 online water quality testing analyzer carefully developed by Erun Environmental Protection is designed and produced according to the standard of GB/T 1576-2018 Industrial Boiler Water Quality.This on-line industrial boiler water quality analyzer is fully functional, capable of accurately measuring the concentration of a number of water quality parameters including hardness, total alkalinity, phenolphthalein alkalinity, PH, conductivity, total dissolved solids, turbidity, dissolved oxygen, ferrous ions, oils in water, phosphates and more.The boiler water quality monitoring equipment is widely compatible with a variety of boiler types, such as oil-fired boilers, gas-fired boilers, coal-fired boilers, biomass boilers, electric boilers and waste heat boilers, etc., and is suitable for continuous, real-time on-line monitoring and analyzing of their raw water, deionized water, supplemental water, condensate, and steam return water.
watery | Parameters | Recharge water Type | Pseudolaric acid | Product Model | Specification | illustrative diagram |
water supply | turbidity | Water softening, desalination | Water Turbidity Analyzer | ERUN-SZ4-A-B6 | (1)Measuring range: 0.1~1000NTU or 0.1-4000NTU (2)Accuracy: ±2% of display value or ±0.02NTU (3)Resolution: ±0.5% or 0.3 NTU (4)Working temperature: 0-50°C (5)Cable length: 10m (standard, customizable) (6)Self-cleaning system: Yes (optional) (7)Protection class: IP68 (8)Detection principle: 90° scattered light | |
durometer | Water softening, desalination | Water Hardness Analyzer | ERUN-SZ3-B2 | (1)Measuring range: (0~200/500/1000) mg/L; customizable (2)Display value error: ±10% (3)Repeatability: ≤3% (4)Zero drift: ≤±5% F.S. (5)Range drift: ≤±5% F.S. (6)Minimum maintenance cycle: ≥168 h/time (7)Digital communication: RS232, RS485, RJ45 (8)Analog communication: (4~20)mA input; (4~20)mA output (9)Ambient temperature: (5~40)℃ (10)Instrument size: 300mm x 420mm x 240mm (W x H x D) (main unit) (11)Instrument weight: <15 Kg | ||
water supply | PH | Water softening, desalination | Water pH Analyzer | ERUN-SZ4-A-B7 | (1)Measuring unit: 0-14pH (2)Working temperature: 0~50℃ (3)Accuracy: ±0.02 PH (4)Electrode material: POM + titanium alloy (5)Protection class: IP68 (6)Calibration: 2-point or 3-point calibration (7)Cable length: standard 10m (can be customized) (8)Detection principle: Electrode method | |
conductivity | Water softening, desalination | Water quality conductivity analyzer online | ERUN-SZ4-A-A4 | (1)Measuring range: 0.001 ~5mS/cm or 0.001~100 mS/cm (other ranges can be customized) (2)Working temperature: 0~50℃ (optional high temperature electrode) (3)Cable length: 10m (standard, customizable) (4)split (5)Electrode material: nickel + PEEK + titanium alloy (6)Protection class: IP68 (7)Detection principle: four-electrode method | ||
dissolved oxygen | Water softening, desalination | Water quality dissolved oxygen online analyzer | ERUN-SZ4-A-A5 | (1)Measuring range: 0~20mg/L, or 0-200% saturated oxygen (2)Working temperature: 0-50°C (3)Accuracy: ±1% or 0.3mg/L (4)Calibration: one or two point calibration (5)Electrode Material: 316L/Titanium Alloy (6)Installation: Flow-through type (with flow-through tank) (7)Cable length: standard 10m (can be customized) (8)Protection class: IP68 (9)Detection principle: fluorescence method | ||
water supply | oil | Water softening, desalination | Oil in water on-line analyzer | ERUN-SZ4-A-J4 | (1)Detection range: 0-50ppm (optional 0-150ppm) (2)Resolution: 0.01ppm (3)Linearity: R2>0.999 (4)Protection class: IP68 (5)Temperature range: 0-50°C (6)Cable length: 10m standard, customizable (7)Self-cleaning system: Yes (optional) (8)Calibration method: zero, one or two point calibration (9)Housing Material: 316L/Titanium Alloy (10)Detection principle: UV fluorescence method | |
iron | Water softening, desalination | Water quality total iron online analyzer | ERUN-SZ3-H3 | (1)Measurement range: (0~5/10/20) mg/L; customizable (2)Display value error: ±5% (3)Lower limit of quantification: ≤0.05 mg/L (4)Repeatability: ≤3% (5)Zero drift: ≤3% (6)Range Drift: ≤3% (7)Minimum maintenance cycle: ≥168 h/time (8)Digital communication: RS232, RS485, RJ45 (9)Analog communication: (4~20)mA input; (4~20)mA output (10)Ambient temperature: (5~40)℃ (11)Instrument size: 300mm x 420mm x 240mm (W x H x D) (main unit) (12)Instrument weight: <15kg |
| |
boiler water | alkalinity | Water softening, desalination | Water Alkalinity Online Analyzer | ERUN-SZ3-B3 | (1)测量范围:(0~200/500/1000) mg/L;可根据客户需求定制 (2)示值误差:±10% (3)定量下限:≤1 mg/L (4)重复性:≤3% (5)零点漂移:≤3% (6)量程漂移:≤3% (7)最小维护周期:≥168 h/次 (8)数字量通讯:RS232、RS485、RJ45 (9)模拟量通讯:(4~20)mA输入;(4~20)mA输出 (10)环境温度:(5~40)℃ (11)仪器尺寸:300mm×420mm×240mm(W×H×D) (12)仪器重量:<15kg |
|
Phenolphthalein Alkalinity | Water softening, desalination | Water quality phenolphthalein alkalinity online analyzer | ERUN-SZ3-B8 | (1)Range: Low range 0.2 ~ 5mmol/L, High range 0.8 ~ 20mmol/L (2)Measurement method: Titration colorimetry (3)Measurement time: approx. 3 minutes, depending on phenolphthalein alkalinity concentration and set rinse time (4)Accuracy: ±5% of the maximum value of selected reagents (5)Repeatability: ±2.5% of the maximum value of selected reagents (6)Reagent consumption: 0.05-0.6mL/per analysis (7)Reagent expiration date: 2 years from the factory (8)Automatic cleaning: the instrument will be cleaned automatically after each measurement (9)Calibration: Service menu manual calibration (10)Temperature of water samples: 5-40℃ (11)Water quality requirements: clear, colorless, no suspended solids, no air bubbles, pH>8.2 (12)Protection class: IP65 (13)Dimensions: 300 x 300 x 200 mm | ||
boiler water | PH | Water softening, desalination | Water pH Analyzer | ERUN-SZ4-A-B7 | (1)Measuring unit: 0-14pH (2)Working temperature: 0~50℃ (3)Accuracy: ±0.02 PH (4)Electrode material: POM + titanium alloy (5)Protection class: IP68 (6)Calibration: 2-point or 3-point calibration (7)Cable length: standard 10m (can be customized) (8)Detection principle: Electrode method | |
conductivity | Water softening, desalination | Water quality conductivity analyzer online | ERUN-SZ4-A-A4 | (1)Measuring range: 0.001 ~5mS/cm or 0.001~100 mS/cm (other ranges can be customized) (2)Working temperature: 0~50℃ (optional high temperature electrode) (3)Cable length: 10m (standard, customizable) (4)split (5)Electrode material: nickel + PEEK + titanium alloy (6)Protection class: IP68 (7)Detection principle: four-electrode method | ||
sodium pyrophosphate | Water softening, desalination | On-line analyzer for phosphate in water | ERUN-SZ3-E3 | (1)Measuring range: 0-20 mg/L (ppm) (2)Measurement error: ±1% F.S. (3)Resolution: 0.01 mg/L (ppm) (4)Measurement channels: 1-4 channels (5)Measurement period: 8 minutes (6)Reagent type: 1 reagent + demineralized water (7)Reagent consumption: 2L/30 days (8)Power supply: DC 24V power supply / AC 220V (9)Flow rate of water samples: 80-120mL/min (10)Temperature of water samples: 5-50℃ (11)External dimensions: 680×450×190mm (L×W×D) (12)Opening size: 645 x 400m |
1、protective function | IP68 for sensor electrodes, IP65 for transmitter integrated cabinet |
2、Range resolution: | Hardness: Range 0.002mmol/L~5.000mmol/L (i.e. 0.20-500.00ppm); Resolution 0.001 mmol/L Total alkalinity: range 0.094 ~ 33.77 mmol/L (i.e., 4.69 ~ 1688.4 ppm); resolution 0.001 mmol/L Phenolphthalein alkalinity: range 0.2 ~ 20mmol/L PH: range 0.00-14.00; resolution 0.01 Conductivity: Range 0.1-2000 μs/cm; Resolution 0.1 μs/cm Turbidity: Range 0.0001-100 NTU (FTU); Resolution 0.0001/0.001 NTU (FTU) Dissolved oxygen: Range 0-200μg/L(ppb), 0-20.00mg/L(ppm); Resolution 0.1μg/L(ppb), 0.01 mg/L Iron: Range 0.01-6.0 mg/L (ppm); Resolution 0.01 mg/L (ppm) Oil: Range 0-100ppm; Resolution 0.1ppm Phosphate: Range 0-20 mg/L (ppm); Resolution 0.01 mg/L (ppm) |
3、Accuracy error: | Hardness: ±5% of the upper limit value of the selected reagent Full alkalinity: ±2% of the upper limit of the selected reagent Conductivity: ±1% or 1 μs/cm, whichever is greater Turbidity: ±2% of reading or ±0.02 NTU, whichever is greater Dissolved oxygen: μg/L (ppb): ±1.0% F.S.; mg/L: ±0.5% F.S. Iron: ±10% Oil: ≤±2%F.S. Phosphate: ±1% F.S. |
4、Display: | The transmitter display shows the concentration value in real time and can be integrated with a 7-inch LCD touch screen with LED backlighting. |
5、Working power supply: | AC220V、50/60HZ |
6、Data Transfer: | RS 485(Modbus RTU)、4-20mA, relay output, etc., optional wireless transmission module + ERUN cloud platform |
7、Data storage: | Historical data can be queried, support for U disk export |
8、Inlet pressure: | 1-2bar (Pressure reducing valve is recommended for high pressure) |
9、Ambient temperature: | 0-50 ℃ 15, water sample temperature: 0-40 ℃ |
10、Inlet/outlet connections: | 6mm/10mm Hose |